ASA510 Translation Module
Specifications and Features
| compact, absolutely measuring unit with hard-wired sensor | |
| accuracy class 0.05 mm, resolution 0.01 mm | |
| interfaces SSI or RS485 | |
| scale MB500 | |
| band/sensor gap max. 2.0 mm | |
| max. measuring distance 655 m | |
| maintenance-free backup battery |
Frequently Asked Questions
Can you suggest a terminal emulator to use with the command generator?? Yes -go to https://sites.google.com/site/terminalbpp/ - with this tool you can copy the hex string created by the command generator and paste it to the send field of the terminal emulator - your talking SIKOnet3 to an ASA510!
Sensor and translation module gather positional changes absolutely, even in the dead state. The system is particularly suited for very long distances with relatively rough distance tolerances.
Downloads
ASA510 data sheet.pdf, 0.12 MB, English
ASA510 data sheet.pdf, 0.12 MB, English
ASA510 Command Generator.html, 0.02 MB, English
ASA510 user information.pdf, 1.36 MB, English
ASA510 SSI timing diagram.PDF, 0.04 MB, English
Ordering
Please call 734-426-3476 for ordering information.