; ;================================================================= ; GSD-Datei fuer SIKO Positionierantrieb AG04 ; mit SINEC L2-DP Schnittstelle ; Stand : 02.06.2008 - Christian Hoffmann ;================================================================= ; #Profibus_DP ; ;--- general Parameter --- ; GSD_Revision = 1 Vendor_Name = "SIKO GmbH" Model_Name="AG04_PB" Revision = "Revision 1" Revision_Number = 01 Ident_Number = 0x0B8C Protocol_Ident = 0 Station_Type = 0 FMS_supp = 0 Hardware_Release = "V1.00" Software_Release = "V1.00" ; 9.6_supp = 1 19.2_supp = 1 93.75_supp = 1 187.5_supp = 1 500_supp = 1 1.5M_supp = 1 3M_supp = 1 6M_supp = 1 12M_supp = 1 ; MaxTsdr_9.6 = 60 MaxTsdr_19.2 = 60 MaxTsdr_93.75 = 60 MaxTsdr_187.5 = 60 MaxTsdr_500 = 100 MaxTsdr_1.5M = 150 MaxTsdr_3M = 250 MaxTsdr_6M = 450 MaxTsdr_12M = 800 ; ;--- Slave spezifische Werte --- ; Redundancy = 0 Repeater_Ctrl_Sig=0 24V_Pins = 0 Implementation_Type = "SPC3" ; Freeze_Mode_supp = 1 Sync_Mode_supp = 1 Auto_Baud_supp = 1 Set_Slave_Add_supp = 0 User_Prm_Data_Len = 1 User_Prm_Data = 0x00 Min_Slave_Intervall = 1 Max_Diag_Data_Len = 6 ;6 byte standard diagnosis Slave_Family = 1 ;1 = Antrieb Modular_Station = 0 ; ; Module ; Module="7 Worte IN/OUT konsistenz"0xF6 ; EndModule ;